October 2026 — We have taken the smallest bore of the Endress+Hauser Proline Promag H 300 family into stock. The DN2 (1/12 inch) unit, order code 5H3B02-AAIBAEAFBAFDCS0BA2, is configured at the factory and packed in original Endress+Hauser cartons, ready for projects that meter a few litres per hour rather than a few cubic metres.
Small hygienic lines fail quietly. An oversized meter still reads, but the resolution at the bottom of its span is too coarse for a dosing step, and the operator starts trimming batches by hand. Keeping a DN2 sensor on the shelf lets a skid builder size the instrument to the line instead of throttling a larger one.
The measuring tube is full bore behind a PFA liner, so there is no constriction to trap product between batches, and the sensor drains cleanly at the end of a CIP cycle. The transmitter is the same platform used on the larger sizes, which keeps spares, parameter sets and operator training common across a plant.
| Order code | 5H3B02-AAIBAEAFBAFDCS0BA2 |
| Nominal diameter | DN2 (1/12 in) |
| Measurement error | ±0.5 % o.r. ±1 mm/s; 0.2 % option available |
| Medium temperature | –20 to +150 °C |
| Max. process pressure | PN 40, Class 150, 20K |
| Liner / electrodes | PFA / 1.4435 (316L), Alloy C22, tantalum, platinum |
| Hygiene | 3-A and EHEDG design basis, FDA-compliant wetted materials |
| Outputs | 4-20 mA HART, pulse/frequency, status output |
Two engineering points decide whether a DN2 installs cleanly: medium conductivity should reach at least 5 microsiemens per centimetre, and about 20 microsiemens per centimetre for demineralised water; and the tube should stay full at zero flow, with roughly 5 DN of straight run upstream and 3 DN downstream. On plastic or lined pipe, grounding rings are needed and can be supplied with the same order.
The unit is offered at a minimum order quantity of one piece with payment by T/T or L/C and a 12-month warranty. Stock normally ships within three to five working days. Send us the dosing volume, cycle time and product conductivity, and we will confirm that DN2 is the right bore before the order is released rather than after it is installed.
Contact our instrumentation team for stock confirmation, datasheets and lead times.
October 2026 — We have taken the smallest bore of the Endress+Hauser Proline Promag H 300 family into stock. The DN2 (1/12 inch) unit, order code 5H3B02-AAIBAEAFBAFDCS0BA2, is configured at the factory and packed in original Endress+Hauser cartons, ready for projects that meter a few litres per hour rather than a few cubic metres.
Small hygienic lines fail quietly. An oversized meter still reads, but the resolution at the bottom of its span is too coarse for a dosing step, and the operator starts trimming batches by hand. Keeping a DN2 sensor on the shelf lets a skid builder size the instrument to the line instead of throttling a larger one.
The measuring tube is full bore behind a PFA liner, so there is no constriction to trap product between batches, and the sensor drains cleanly at the end of a CIP cycle. The transmitter is the same platform used on the larger sizes, which keeps spares, parameter sets and operator training common across a plant.
| Order code | 5H3B02-AAIBAEAFBAFDCS0BA2 |
| Nominal diameter | DN2 (1/12 in) |
| Measurement error | ±0.5 % o.r. ±1 mm/s; 0.2 % option available |
| Medium temperature | –20 to +150 °C |
| Max. process pressure | PN 40, Class 150, 20K |
| Liner / electrodes | PFA / 1.4435 (316L), Alloy C22, tantalum, platinum |
| Hygiene | 3-A and EHEDG design basis, FDA-compliant wetted materials |
| Outputs | 4-20 mA HART, pulse/frequency, status output |
Two engineering points decide whether a DN2 installs cleanly: medium conductivity should reach at least 5 microsiemens per centimetre, and about 20 microsiemens per centimetre for demineralised water; and the tube should stay full at zero flow, with roughly 5 DN of straight run upstream and 3 DN downstream. On plastic or lined pipe, grounding rings are needed and can be supplied with the same order.
The unit is offered at a minimum order quantity of one piece with payment by T/T or L/C and a 12-month warranty. Stock normally ships within three to five working days. Send us the dosing volume, cycle time and product conductivity, and we will confirm that DN2 is the right bore before the order is released rather than after it is installed.